It could also be a tiny bit of condensation against the diaphragm. It says Remote TSTAT enabled, which I believe is for my Jandy remote. Please include what you were doing when this page came up and the Cloudflare Ray ID found at the bottom of this page. So, without a working igniter, you cant get your Jandy pool heater to light up. Worked until yesterday. July 6, 2016 in All Swimming Pools Types. I removed the front panel and I see the wiring and boards in there. It's well worth a call out charge to have a qualified gas plumber check flow and pressure for you. Walked over to heater and it said "CHECK IGN STEPS". I will need to rig up some kind of coat hanger or something to pull out some of that debris under there. I know you've reported it doesn't light at all but please check again. First time I got this it happened randomly. Write Review Jandy JXi/LXi Ignition Control Kit | R0456900 $392.48 So you disconnect the wire from the air flow switch and put it back on and the units fires up OK? Then it worked for 2 months and now will not fire up. This means my water pressure sensor is working because that goes away when the pump is on. You can call Jandy customer care Monday through Friday, 8 AM-5 PM (PST) on this number- 800.822.7933 or send an email to the following address- productsupport@fluidra.com. Look at the glass eyeball to see if you see the igniter glowing. Let's look at various approaches to fix faulty combustion. 16. JavaScript is disabled. If backwashing the pool filter doesnt help you, you need to identify which of the reasons mentioned above is causing the issue. For a better experience, please enable JavaScript in your browser before proceeding. Next step is the blower itself. It may not display this or other websites correctly. I keep reading the intake is on the bottom of the heater, but then there's this air pressure slider on the side which is adjustable. Any thoughts or suggestions appreciated as I wait for the gas company to install a new meter in about 3 weeks.. which I do not really expect to solve the problem. I should also add if you do not have training and experience with gas plumbing please get a qualified gas plumber to do this for your. Get the leads and connect one on each terminal once youve located the terminals. This switch has air tubes plugged into the main fire box down below. To connect the hose to the bib, turn it clockwise. cycles through this 3 times them displays the ags error. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. 5 5 comments Best Add a Comment TehSpaz 5 yr. ago Check to see if your weirs hinges are still working properly and repair any damaged or jammed doors. The problem may also be in the wiring or the blower may be getting an inadequate voltage supply. You will get much more visibility by. Jandy Lxi Heater Won't Start! - Pool and Spa Forum ILL LET YOU KNOW HOW I MAKE OUT. Another pool season another heater issue Mastertemp 400 wont start, no error codes, JXi Heater - how do I check to see if the air flow sensor is working right, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. You cannot paste images directly. This identifies the bad connection. Low gas supply pressure can also cause a Jandy JXi pool heater ignition fault. Oh, and gas valves very rarely go bad. Install Piping and Check Gas Supply. Vocational, Technical or Tra. Jandy Pool Heater Won't Ignite [7 Easy Solutions] 1. As title states, I have a 4 year old heater, Jxi model, natural gas. This was done for safety and to be sure wires didn't accidentally come loose and short out which could short out electrical components. There are several potential causes, most pretty easy to fix but require taking some of the heater panels off. I can't really see "under" my heater because it is sitting right on the ground. I'd start by following the trouble shooting guide & test the voltage at the points in that guide. It is Propane I know that much. I know you've reported it doesn't light at all but please check again. I traced this using the trouble shooting guide to the air pressure sensor. Then the ignitor will time out after 5 sec if the flame sensor does not sense ignition. Place your test meter on VAC (AC Volts), on a low scale 100 or 200 volts. You should smell gas if it is the ignitor as it tries to light and then gives up. The start sequence almost completes going through spinning up the fan and heating up the ignighter then there's this loud buzz and it stops the cycle. For Natural Gas: Minimum 4.0 W.C. to Maximum 10.5 W.C. For Propane: Minimum 4.0 W.C. to Maximum 14 W.C. It is being practiced by thousands of pool owners just like you. An additional puzzling item you describe is the lack of red LED flashing. After doing so, the heater started up just fine for about a week. Vocational, Technical or Tra. All Right Reserved by HeaterFixLab. I am a new pool owner and am frustrated with our brand new Jandy LXi gas heater. You think? Check the fuse or reset the breaker. Inspect the gas supply inlet pressure. You can post now and register later. With great help from experts on this site I was able to fix even this at way less than 30% the cost of a replacement. Upload or insert images from URL. JANDY 200 INSTALLATION AND OPERATION MANUAL Pdf Download I have Jandy LRZ Legacy Natural gas heater. Our installer could not find anything wrong with the unit, so he surmised it was caused by insufficient gas pressure. Powered by Invision Community, Inground, Fiberglass and Aboveground Swimming Pools, Jandy Lxi 250 Heater - Fault Check Ign Control. Set the multimeters test control to mV,. Walked over to heater and it said "CHECK IGN STEPS". Ideally I'd like to jack up the heater an inch or two but I have all my water pipes plus my gas line connected, and it would be really hard to move it more than like 1cm w/out stressing a pipe Not sure what else to do here, other than turn to a local Jandy authorized serviceman and have him check it out.. Let me know if you do not have a LoNox, i have different flow chart for them. If not, the blower motor may be at fault. That usually happens to a service tech at least once. I looked inside the burner tubes and did not see any evidence of spider webs or insects. This is where I learned almost everything I know about this and similar heaters the only good thing that came about from my lightning strike that caused over $5K damage. For a better experience, please enable JavaScript in your browser before proceeding. Jandy lxi not heating, getting ignition fault, help. Water Connections. The wires trace right so it must be. My heater is giving me a code after about one minute of heating up. PB came out and ( I think) replaced a circuit board. When the gas valve opens, you can smell the methyl mercaptan so I know there is gas getting in to the combustion chamber. Could be a connection issue. Bad Flame Sensor 3. I might call Jandy, but am hoping I can get some more ideas here. Serving Monmouth and Ocean counties and The Princeton Route 1 corridor communities. I saw the spa hit 100 deg and got my suit on. I am now not certain where it actually connected or how to get a replacement part for it. Your next thing to do is to verify gas supply. Power cycle the heater to clear the code, try it again the next day- same thing, 65 degrees to 84 totally fine then the error. Amazing, we also had the ignition issue, haven't used the lxi400 for 2 seasons. http://www.northamericahvac.com/servlet/the-5245/Honeywell-Air-Pressure-Switch/Detail. Section 12. Your previous content has been restored. Bad Igniter 5. The pressure switch prevents the burner from operating if the pool water pump fails or the water filter becomes clogged. During the piping pressure test, close the manual shutdown valve on the heater if the test pressure is equal to or less than 1/2 psi (3.45 kPa). In fact, his aim is to help his readers to fix the issues with their heating appliances easily.More about us . Defective Igniter 4. Next stupid question: How do I see the ignitor? I believe the click you are hearing is the gas valve relay. The gas control valve is incredible reliable. He also checked the inlet gas but not the outlet. PoolSpaForum.com Heres how. During this process, there is no heat generated at allit doesn't fire. Sorry for the delay, don't know if you still need this but here's what I did: The tech could not find the corroded wire. Make a note of where the wires join the valve so you can reconnect them later. $20 OFF Chlorine Flash Sale. Jandy LXi CHK IGN FAULT - YouTube That happened to me an caused a month of incredibly frustrating troubleshooting. A gas regulator failure for a 4 year old heater is extremely rare.. Do you have access to a gas manometer? Did you cycle the breaker after recommended? 203.217.168.41 INSTALLED LARGER METER, NO CHANGE. https://www.doheny.com/media/Pdfs/7609-instructions.pdf, JXi Heater - how do I check to see if the air flow sensor is working right, Pool heater is working but not heating water. PB is coming out again to check. You will get much more visibility by. You will have to replace it. This may mean you need to do more in-depth work to determine if it is faulty. How to Troubleshoot Jandy Jxi/Lxi Pool Heaters - Pool Party App Not solid either. Section 11. Jandy Lxi 250 Heater - Fault Check Ign Control - Pool and Spa Forum Easy replacement. Has anyone ever had this code? This test must be carried out with the power turned on. I assume they were living in there this past winter. If it does you don't need to replace the igniter. Locate the hose bib to bleed away air after shutting off the water heater. The possible causes include- fluctuating filter pump pressure, faulty flame sensor, bad pressure sensor, damaged fan/switch tubing, fan not operating or running slowly, restricted airflow, low gas supply pressure, malfunctioning gas valve, and air in the gas line. blower comes on, ignitor glows then blower goes off and ignitor turns off. Disconnect power at the breaker. It's not super expensive but we see a lot replaced that are good. I can shut off power and have at it, just dont know where to start. Seemed to fire up normally, whoosh and heat blowing etc. If this doesn't work then you should look at the red light on the top side of the grey fenwal ignition module (as shown in photo below) blinks and count the number of times it blinks. It may not display this or other websites correctly. I still am not getting any blinking at the LED on the panel. Upload or insert images from URL. Raypak low NOx heater only works if I hot start it, I'm out of my mind, what am I missing? You need to test the pressure switch for continuity with a multimeter. The clicking I hear is the igniter turning off I guess. Do I need to use a mirror on the bottom of the heater? I found one thread on this but it isn't helping: http://www.poolspaforum.com/forum/index.php?showtopic=26484. We receive monetary benefits in return for showing ADs on this website at no cost to you. The heater worked fine last season right before winter. I can't even find the window. The air/gas mixture in the combustion chamber is immediately ignited by the hot surface igniter. I have a jandy LXI 400p. If the gas valve relay makes the loud click and you have no gas odor the only things that can cause that are gas supply or gas control valve. The code that appears on the display says Check IGN Steps and then shuts down. The switch is working fine, but the tube that goes around to the side of the unit was off. Did you remove the switch and blow out the sense lines (tubing) and try to drain anything I that may be in the case out? Thx mike sounds to me like a fuseable link has failed in the exaust. You are using an out of date browser. New valve should be here in a few days, hopefully at same time as plumber. I'd guess flow issue, but that's a guess. The best method is to remove the air from the gas line. I am getting the following fault code on my Zodiac Electronic Heater comes on, flash plate heats up, gas comes on read more. I see some leaves in there, but nothing crazy. With that in mind, if anyone has any ideas, I'd be grateful. Jandy JXi 400 Manuals | ManualsLib I'm trying to find the warranty, it's 4 years old in July 2013 I think. To clean blocked suction pipes, take a high-pressure attachment or drain king. Stupid question: Doesn't the blower fire up and purge the system BEFORE the igniter is triggered? Spark Ignition Pool Heater Troubleshooting Guide Check for correct clearances around the heater and, if the room is enclosed, adequate ventilation. Not sure what else to check. Pasted as rich text. It is being practiced by thousands of pool owners just like you. There can be several reasons why your Jandy pool heater wont ignite. Pool and equipment are about six years old. 38. Doheny's DIY Pool Care Help Center. Next time it fails, without doing anything else, check for voltage across the air switch terminals and the water pressure switch terminals. I had the exact same problem a few years ago when I installed my LAARS 400 without a local regulator. It will run up from 65-80's with no problem then throws the error consistently at that point. It eventually shows an ignition fault. To test for Ohms, double-check that the leads are in the appropriate spot, then grab the switch. If the motor and fan turn freely then usually the ignition module that contains the relay is bad and will need to be replaced. I figured out from the diagram this is actually 120vAC. http://www.jandy-downloads.com/heaters_lxi_manual.pdf, I traced the wires from the "comp ign" switch to the ignitor board. Could it be the gas pressure valve? I backwashed and that seemed to go away. Plus, I still haven't gotten a good answer on which need to be hot, which are negative, etc.. anything may be missing? Propane guy was out and confirmed correct pressure, which I think makes sense since it goes from 65 to 84 in a quick time (20-30 minutes). However, tonight, it had one. Pasted as rich text. I have a Jandy JXI400 heater. JavaScript is disabled. For your pool heater to run, you need the fan to run at a certain pace. Shortly after opening the pool, I had to replace a cracked igniter. No visible evidence of damage on ignitor surface (some high temperature discoloring but no white corrosion or evidence of a crack). Im getting check ign steps error code. Hello , There was no answer in this thread for more than. To inspect the wiring connections, refer to the Jandy pool heater wiring diagram below. Flawless operation, never had an issue ever. You need to figure out which of these possible things are wrong with the blower. I tried to fire it up last weekend and it Ask an Expert Home Improvement Questions Pool And Spa Repair Question Summary Answer Summary Gaztech1 here, just signed in, 9H00 am eastern time in CANADA.good morning..I am ready to assist you with your issue. But no flame, not never (so far). I would pull the ignitor and inspect it. I got resistance when my booster pump came on and none when it was off, so it is working. Gas Pool Heater: JXi Pool Heater | Jandy For a better experience, please enable JavaScript in your browser before proceeding. In order to see it properly you need to release that panel and swing it out if you have not done this yet. COPYRIGHT 2023. You could also try using a steel or brass brush to clean the burners. Cycles through 3 times but won't ignite. If it reads less, the sensor is defective and must be replaced. Clogged Pool Filter 2. I have a jandy LXI 400p. I hear a click after about a minute, two minutes, and three minutes. Hi there, FAULT - CHECK IGN STEPS Causes: 1.Broken, split, pinched or disconnected fan/switch tubing.2.Fan not operating.3.Fan running slow or premature fan failure.4.Air flow restricted at intake or discharge.5.Oscillating pump pressure.6.Low gas supply pressure.7.No flame at burners. It's funny cuz the blower makes it sound like the heater is working, but alas it's just my shop-vac moving the same air in that chamber.
Jbsa Randolph Pharmacy Formulary, Today's Taylordle Hint, Nova The Planets Transcript, Mr Platt Orthopaedic Surgeon, Breaking News In Randolph County, Nc, Articles J